EGIL200 circuit breaker analyser
Circuit breaker time and travel analyser with DualGround™ testing
Circuit breaker time and travel analyser with DualGround™ testing
Key Benefits
- Intuitive and user-friendly operation
- One-click reporting
- Multi-functional control channels
- Patented Active Interference Suppression technology
Description
The EGIL200 circuit breaker analyser has been developed in response to demands for an affordable mid-range circuit breaker analyser that is fast and easy to use. The emphasis in the EGIL200’s development has been on ease of use, ensuring that the time spent setting up measurements is kept to a minimum. With the quick test mode, all relevant settings are on one screen, ready to select and begin testing.
Ideally suited for testing high and medium voltage circuit breakers in substation and industrial applications, this versatile instrument offers a wide range of functions. All recommended measurements specified in the IEEE C37 and IEC 62271 standards are included.
The EGIL200 is based on technology used in Megger’s market-leading EGIL and TM series of circuit breaker analysers, combining their ease of use with many other features that have made them so popular. These features include PIR contact timing and PIR resistance measurements, which are accurate even in noisy environments, thanks to their Active Interference Suppression technology. Other key features of the EGIL200 include its one-click report generation ability. You can upload results to a PDF file or send them directly to an optional integrated printer. The EGIL200's robust construction makes it suitable for operation in even the most demanding on-site conditions.
Connection to the test object has also been streamlined, so you only need to connect the test leads once to perform all the following measurements or operations:
Timing of main and PIR contacts
Coil current analysis of close, open 1 and 2 coils
Station voltage measurements
Motion measurements
Resistance measurements, static and dynamic
Motor current measurement
Minimum pickup voltage test for close, open 1, and open 2
The EGIL200 can be supplied in versions that are pre-configured for standard applications, such as medium voltage, high voltage, and dead-tank breaker testing, or in a fully customisable configuration that supports up to four breaks per phase and three analogue inputs.
Specifications
Frequently Asked Questions
Why test circuit breakers?
There are many reasons for testing circuit breakers. Some of the most important are to ensure they: Protect expensive equipment Prevent outages that lead to loss of income Provide reliability of the electricity supply Prevent downtime and darkness Perform as expected
What is a pre-insertion resistor (PIR), and is it necessary to test it during timing?
Some circuit breakers are equipped with pre-insertion resistors (PIR) for closing operations, typically on higher voltage transmission CBs or capacitor bank applications. The PIR closes first (typically 5 to 10 ms), and then the interrupter closes afterward. The PIR protects the breaker contacts from overvoltages and inrush currents. Therefore, accurate timing and measured values of the PIRs are crucial to ensure the circuit breaker is operating correctly, preventing circuit breaker failure and damage to the contacts. For a more detailed explanation of PIRs, refer to the Megger circuit breaker application guide.
Does the EGIL200 store results, or do I need a computer?
The EGIL200 has on-board memory and software that allows you to store your results directly onto the unit. Each circuit breaker is saved as a unique asset, and a record of each test will be saved under the circuit breaker. The individual breakers can be exported to software on a PC for data storage as well.
Do I need or can I control and operate the EGIL with a PC?
No, the EGIL is a standalone unit operated by the built-in 7-inch touch screen. You can export results to a PC for storage and analysis, but all testing is performed directly onboard the EGIL.
I have an older Megger/Programma test set (EGIL, TM). Are the results compatible?
The TM units and the previous EGIL use CABA Win and .arc files to control the units and analyse and database results. The EGIL200 has switched to a .zip file. You can convert older .arc files through CABA Win, and you can import this file onto the EGIL, where you can view previous results and add a new test to the same file. You can also view EGIL200 files in CABA Win, but you cannot use the software to control the unit.
Is the EGIL200 simple to connect and operate?
The EGIL was designed with safety and simplicity at the forefront. The on-screen, breaker focussed test setup is simple and intuitive to use. The on-screen connection diagram highlights all channels in use, so you don’t miss a connection.
How many coil currents can the EGIL measure?
The EGIL200 will measure the open and close coil currents through the control cable connection for gang-operated circuit breakers. For circuit breakers with three operating mechanisms, the EGIL will measure and graph the total coil current through the control connection but provides three independent inputs for a CT clamp to measure individual coil currents.
Does the EGIL have a built-in power supply for the CB?
The EGIL is a lightweight, portable circuit breaker analyser, so a power supply is not incorporated to save weight, given the majority of times when you want to test with station voltage. When a variable voltage supply is needed, Megger has a B10E accessory that can power the circuit breaker.
What if my EGIL lacks channels or if I need more advanced testing?
The EGIL can be configured to test up to four breaks per phase and three motion channels simultaneously. If the EGIL doesn’t have enough channels to test everything at once on the circuit breaker, or you have custom test plans you want to create or work with, Megger recommends our TM line of circuit breaker analysers that can provide more advanced testing. You should note that the EGIL allows testing phase by phase, so this option can be used if there are insufficient channels on the EGIL200.
When should a circuit breaker be tested?
Testing should be done at various stages in the life of a circuit breaker, including: Development Production Commissioning Maintenance/fault tracing After service (re-commissioning)
What should I measure when performing circuit breaker testing?
The manufacturer typically provides a list of the parameters you should check and the range of values you should expect. The list can vary by breaker design, but if none is provided, at a minimum, you should measure the following: Main contact times Pre-insertion resistor (PIR) contact times, if present Max contact time difference between phases Stroke Overtravel Rebound Velocity Coil current Station voltage Contact resistance
What types of circuit breakers does the EGIL200 test?
The EGIL is a time and travel analyser used to test medium voltage (MV) to extra-high voltage (EHV) AC circuit breakers (CBs). There are many different types and designs of AC CBs. However, from a testing perspective, there are two main types: Low voltage (LV) circuit breakers that have intelligence built in to trip automatically when the current exceeds a specific value for a certain amount of time. High voltage (HV) circuit breakers that depend on relays powered by station voltage to tell the CB when to operate. LV circuit breakers, rated up to 1000 V, are tested by injecting current through the contacts and measuring the time it takes to interrupt the current. These circuit breaker types are tested with a primary current injection unit such as the Megger SPI, Oden, and DDA. The EGIL is a circuit breaker time and travel analyser designed to test distribution and transmission CBs. The EGIL sends a control pulse to the CB and measures the time it takes for the contacts to separate or make contact, depending on the operation. The EGIL can be configured with different channels. Therefore, the types of circuit breakers it can test depend on the number of channels in the EGIL and the number of breaks the circuit breaker has. The EGIL200 is designed to test in high noise environments and can test circuit breakers up to 765 kV.
What configuration of the EGIL200 does Megger recommend?
There are multiple configurations of the EGIL available, and your ideal configuration depends on the type of CBs you have and the measurements you want to perform. If you only have MV CBs to test, i.e., rack in, rack out, and vacuum type, then the EGIL211 is all you need. This configuration can test one break per phase of all three phases simultaneously and has one analogue input for measuring the travel or motion of the interrupter. As you move up in voltage levels and into transmission-type CBs, the breaker may have multiple breaks per phase and multiple operating mechanisms. The correct EGIL will need to be selected based on the maximum number of breaks per phase and the number of mechanisms your CBs have. The EGIL200 can be configured to measure up to four breaks per phase and three operating mechanisms simultaneously. If you are planning on testing transmission breakers, an option with three analogue channels and a high voltage lead kit is necessary. We also recommend opting for a minimum of two breaks per phase to ensure flexibility. The EGIL software allows for testing a CB phase by phase in case you do not have enough channels to test all contacts simultaneously.
Can the EGIL200 be upgraded after purchase?
The hardware of the EGIL is set once it is built, so it cannot be upgraded. You can add some optional features later with software or hardware accessories. The software can be upgraded to use these additional features and accessories if the EGIL has enough channels.
Are there any accessories recommended for the EGIL200?
With a multitude of different circuit breaker (CB) designs and manufacturers, there are many different tests that you can perform. Some tests are common to all CBs, and some design specific. Megger has an extensive set of accessories available for comprehensive testing of your circuit breaker. You can order the EGIL with different lead sets based on the breakers you will encounter. These will cover the operation of the CB, timing contacts (Main, PIR, Aux), and operational parameters of coil current and station voltage. We also recommend motion transducers and, occasionally, breaker-specific accessories based on the CB you are testing. See the accessories data sheet above for further details.
Should I measure motion (travel) on my circuit breaker?
Travel is an important aspect of a circuit breaker’s operation. With a travel curve, the overall mechanism and interrupter function is evaluated. Critical parameters such as stroke, overtravel, and rebound are recorded, and you can correct faulty operation before excessive wear or damage to the circuit breaker occurs. If you are only measuring timing, note that the circuit breaker times can be within specification whilst the velocity of the interrupter is not sufficient to extinguish the arc. For a complete evaluation of the CB, we always recommend travel measurements.
What type of transducer should I use?
There are two main types of transducers: rotary and linear. Rotary transducers are small and generally easy to mount onto the circuit breaker. However, a conversion table or conversion constant is required to translate rotary motion into linear motion. A linear transducer may be harder to mount to the circuit breaker, but it often provides a one-to-one translation of motion, so no conversion is required. The type of transducer needed depends on the manufacturer, breaker, and mechanism. Typically, a rotary transducer is required for live tank breakers. A linear transducer is most often required for vacuum, dead tank SF6, and bulk oil circuit breakers. It is best to consult the circuit breaker manual or manufacturer, but a general rule of thumb is a small linear transducer, 50 mm or less, for vacuum circuit breakers, a digital rotary transducer for live tank SF6 breakers (and some SF6 dead tank), a 200 to 300 mm linear transducer for SF6 dead tank circuit breakers, and a 500 to 600 mm linear transducer for bulk oil circuit breakers. Megger has multiple linear and rotary transducer mounting kits that you can use on various circuit breakers as well as manufacturer and mechanism-specific circuit breakers to meet all your transducer needs. Check the circuit breaker accessories guide for a list of transducers available.
Documents
- EGIL200_DS_en.pdfpdf 2.04 MB
- Egil200_UG_en.pdfpdf 1.93 MB
- Circuit_Breaker_Testing_Catalogue_ENpdf 6.99 MB
- Circuit-breaker-accessories.pdfpdf 3.56 MB
- Circuit_Breaker_Testing_Guide_AG_EN.pdfpdf 14.53 MB
- Motion test with EGIL200.pdfpdf 823.33 KB
- Minimum pick up voltage test with EGIL200.pdfpdf 411.29 KB
- EGIL200-AN_CB-Timing-EN-V01.pdfpdf 734.08 KB
- EGIL200- Dynamic resistance measurement_AN_EN.pdfpdf 1.49 MB
- EGIL200-Static resistance-SDRM-EN.pdfpdf 1.13 MB
- EGIL200_AN_Under-voltage_release_EN_V01.pdfpdf 477.48 KB
- EGIL200-AN-Static-Manual-EN-V01.pdfpdf 309.33 KB