Technical equipmentWith O2/CO (H2 comp.) Longlife sensors (life span higher than 4 years by normal load), Automatic CO-switch-off and sensor purging (without measurement interruption), Condensate trap resp. gas cooler incl. electronic condensate monitoring (depending on selected model variant), Powerfull Lithium-Ion battery, Gas cooler with automatic condensate evacuation, Integral thermal quick-printer, High-value gas sampling probe incl. thermocouple, fixation cone and high-value 3-chamber gas sampling tubing, Status display for indication of basic functions, adjustments and warning messages, Complete in ultra-light, robust aluminium housing, T-Room sensor / T-Room stick (according to request resp. model variant), Integral soot measurement (application-related covered in standard delivery scope), Fitted in spacious aluminium-framed transport case with comfort shoulder carrying strap, Calibration certificate - issued after 100% sensors calibration into climatic chamber, Free downloadable PC software, High coverage for bridging distances between measurement place (gas opening) and adjustment system (e.g. burner, control panel, etc.), Incl. thermocouple input, mini USB connector (data transfer to laptop/PC), SD card slot, Backlit foil keypad and high-value colour TFT display, Indication, printout and recording of measurement data, Complete instrument operation command (i. a. manual CO switch-off, start and end of measurements, data processing, …), Stable data transfer via radio (highest avoidance of interferences, bypass of metal or concrete obstacles, automatic connection, no abrupt disconnection, keeping of all measurement values as well as automatic build-up and restoration of radio connection), (L x H x W): approx. 450 x 315 x 250 mm resp. 510 x 330 x 250 mm (depending on selected model version), Approx. 12 kg (complete in transport case)Technical equipment (Notes)Radio Remote Controller, (Included in standard delivery scope), Dimensions, Weight, Testing according to UKCA approved DIN EN 50379-2 and 1st. BImSchV., Data Sheet, Product flyer, Variants:, Data sheet ecom-J2KNpro Expert, Data sheet ecom-J2kNpro EngineBiogasCH4 (NDIR) Sensor, 0-100 % H2S (EC) Sensor, 0-5000 ppm Viton-Entnahmeschlauch, 3 m Data sheet, CH4 (NDIR) Sensor, 0-100 %, H2S (EC) Sensor, 0-5000 ppm, Viton-Entnahmeschlauch, 3 mBiogas (Notes)(Expansion for ENGINE variant), Data sheetMCERTSVariants with O2, CO, NO, NO2 , SO2 possible Stainless steel cooler with electronic condensate monitoring and automatic condensate drain Heated sampling probe (300 mm), cone and NOx tubing (3,5 m), Variants with O2, CO, NO, NO2 , SO2 possible, Stainless steel cooler with electronic condensate monitoring and automatic condensate drain, Heated sampling probe (300 mm), cone and NOx tubing (3,5 m)MCERTS (Notes)Certified to the MCERTS performance standards for handheld emission monitoring systems (HEMS), CertificateOptions (i.a.)NOx calculation via NO sensor or NOx measurement (NO + NO2 sensors) possible, Further optional sensors (SO2, H2S, H2, CO%), Higher resolution and accuracy in NOLow (0-300 ppm) resp. NO2 Low (0-100 ppm) range, CxHy measurement via catalytic measurement principle (Pellistor), Measurement of flow velocity in exhaust gas, Wi-Fi or Bluetooth Low Energy optionAccessories (i.a.)Various gas filtering options – i. a. for recurring solid combustibles measurement, Various temperature sensors (contact sensor, surface sensor, …) for differential temperature measurement (e.g. water run-in and water run-out temperatures), Alternative probe tip lengths and probe tip type (high-temperature) resp. heat protection shield